13 MAY 23 HKL

SITE GROUP
Kadapi J. PROMES: Hujan bossku
 Azman HKL: Iya bossku. Kuat hujan tadi..
Azman HKL: @~ShawnChia @~. boleh kasi siap ni hari?
Azman HKL: 2nd floor. M&E & to rebar in progress.
 Azman HKL: 2nd floor. Zone 4. Beam rebar in progress..πŸ™πŸ™πŸ™
 Azman HKL: Please confirm me. Consultant still stanby for inspection in site. πŸ™now 3pm.
 Kadapi J. PROMES: Guys, can we make it today. I'm still on if u says yesπŸ˜…

 +60 17-866 0355: boleh man
 Kadapi J. PROMES: Mau malam sudah ni. Ada orang belanja makan kah?πŸ˜…
 +60 12-843 3877: M&E insfection
 Azman HKL: Jom...
Kadapi J. PROMES: Azman, please check why our busduct riser out side of the electrical room.
 Kadapi J. PROMES: Jadi mau ka c pindah kita punya opening?


 Azman HKL: Itu bilik tidak salah..
Azman HKL: Sama dengan electrical drawing.
Azman HKL: @~ShawnChia @~. tolong check shopdrawing opening kamu. Kira berapa ukuran dia. Banyak keluar itu.
 +60 17-866 0355: Ok man kita ubah
 +60 16-832 0082: Ini tak boleh salah ya.., DCC person incharge pls confirm betul betul. Tq
 +60 17-866 0355: Ok bos
 +60 16-837 8881: Esok kita double check balik
Kadapi J. PROMES: Ada sikit decrepency between electrical drawing sama archi. Size elect. Room 1st floor dan elect. Room 2nd floor. 1st floor elect. room besar dan 2nd floor jadi kecil. So busduct kena pasang zig zag 'L' shift.
 Kadapi J. PROMES: Klu mau lurus vertical kita punya busduct kena ka c issue. Mlm ni maincon mau cast sdh.
Kadapi J. PROMES: πŸ˜₯πŸ˜₯πŸ˜₯πŸ˜₯
Raymond Chong. Y. F (HKL P. Manager): Azman, bolih selesai ka? Pump tunggu
Kadapi J. PROMES: Sedang bikin. Boleh selesai bah bossku.
Raymond Chong. Y. F (HKL P. Manager): πŸ‘
Azman HKL: DCC sedang buat bos.
+60 12-843 3877: Sudah pindah kedalamπŸ‘πŸ»
Kadapi J. PROMES: πŸ‘ŒπŸ‘
Azman HKL: TQ..🫰

NSC GROUP
Azman HKL: Site progress picture. 13/05/2023
6th floor.
Azman HKL: 2nd floor. Zone 5. Top bar rebar in progress. M&E runs conduit on slab in progress.
 Azman HKL: 2nd floor zone 4. Beam rebar in progress.
Azman HKL: 2nd floor. Zone TB1. Slab & beam formwork in progress.
 Azman HKL: Basement. 7B. Scaffolding beam support for ground floor  in progress.
 Azman HKL: Ground floor. TA1. Slab & beam formwork in progress.
Azman HKL: Basement zone 5a. Ground floor scaffolding support in progress. Lift formwork. Closure in progress.
Azman HKL: M&E runs conduit on slab rebar in progress.
 Azman HKL: Ground floor..brick laye bin center
Azman HKL: Basement..transfomer room concrete stiffener
Azman HKL: Basement..water tank plaster top plint
Azman HKL: For info. 2nd floor. Zone 4. Casting plan is on 15/05/2023, Monday. All NSC please be informed and plan installation accordingly.
Azman HKL: 2nd floor, TB1 casting plan is on 25/5/2023.
 +60 12-843 3877: πŸ‘ŒπŸ»
 Azman HKL: Consultant on site M&E inspection for Plumbing.
Azman HKL: M&E inspection Fire Protection services.
 Azman HKL: M&E inspection electrical and ELV services in progress.
 +60 12-843 3877: M&E insfection
 +60 12-843 3877: πŸ‘πŸ»Done